Core Description

Electric vehicle (EV) charging stations and e-mobility infrastructure operate in exposed outdoor environments, where they face constant risks from lightning surges, grid transients, and switching overvoltages. Without dedicated surge protection, these events can damage sensitive charging modules, control electronics, and low-voltage (LV) distribution panels, leading to costly downtime, safety hazards, and revenue loss. Our UL and IEC certified SPD solutions are purpose-built for e-mobility applications, delivering robust, integrated protection for AC chargers, DC fast chargers, and public charging hubs.

Core Advantages (Visual Bullet Points)

Critical Protection for Sensitive Electronics In EV scenarios such as charging stations and public transportation systems, SPDs are essential to safeguard sensitive electronic components from surge damage.
Reliability of Continuous Power EV systems depend on stable, uninterrupted power delivery. Extreme voltage surges can disrupt charging operations, leading to costly downtime and service interruptions.
Minimized Lightning Risk By installing properly rated SPDs, the risk of infrastructure failure due to lightning strikes is significantly reduced, ensuring continuous, safe operation of charging networks.
SPD Installation Locations & Recommended Types for E-Mobility Infrastructure

A robust protection strategy requires choosing the right SPD type and installing it at every critical point in the charging system. Our solutions are tailored for seamless integration into LV panels and charging cabinets, ensuring complete, coordinated protection.

Installation Location & Recommended SPD Types

Charging Pile Input/Output: Install DC and AC SPDs at the input and output terminals of the charging pile to protect power conversion modules and internal circuits.
Charging Station Distribution Cabinet: Deploy SPDs in the main LV distribution cabinet to provide overall system-level protection against incoming grid surges.
Control & Monitoring Systems: Install SPDs at the input of control systems and monitoring equipment to protect communication boards, PLCs, and SCADA devices.

SPD Selection Guide

Type 1 AC SPD: Suitable for power distribution systems and main charging station protection, handling high-energy surges at the service entrance.
Type 2 AC SPD: Designed for charging pile and control system protection, reducing residual overvoltages before they reach sensitive equipment.
Type 3 AC SPD: Provides fine protection for terminal equipment, offering final-stage surge suppression for user-facing charging modules and communication ports.

Full Page Body Content (Ready-to-Use)

Work Environment (5).jpg

The rapid expansion of EV charging infrastructure has created a critical need for reliable electrical protection. Charging stations are complex systems that connect the public grid to sensitive power electronics and high-voltage batteries. Located outdoors in parking lots, commercial buildings, and public areas, they are constantly exposed to lightning surges, grid disturbances, and switching overvoltages, all of which pose a significant threat to equipment reliability and user safety. A single surge event can disable multiple chargers, damage control modules, and disrupt communication systems, leading to lost revenue, maintenance costs, and user dissatisfaction.

Our surge protection solutions for EV charging stations are engineered to address these unique challenges. Designed for seamless integration into standard LV panels and charging cabinets, our compact DIN-rail mountable SPDs provide multi-level protection for both AC and DC sides. All products are UL 1449 and IEC 61643 certified, ensuring compliance with international safety standards for public and commercial e-mobility infrastructure.

Work Environment (8).jpg

For system integrators and EPC contractors, we provide complete application schemes, installation guidelines, and compliance documents to support project design, commissioning, and acceptance. For charging station manufacturers, our SPDs are optimized for easy integration into new or existing cabinet designs, reducing assembly time and enhancing product reliability. For design engineers, we offer detailed technical parameters, protection level data, and coordination studies to ensure every system meets local electrical codes and safety requirements.

Covering AC 230V/400V and DC 750V/1000V systems, our SPDs effectively suppress surge currents and limit overvoltages, protecting not only power conversion and charging modules but also the critical communication and control systems that keep the charging network operational. This holistic approach ensures maximum uptime, protects your capital investment, and enhances the safety and reliability of EV charging infrastructure for users and operators alike.