T03-A6 Lightning Data Logger
Smart Lightning Monitoring &Warning System
Products Categories
Featured Products

T03-A6 Lightning Data Logger

The T03-A6 lightning data logger is suitable for installation in lightning protection boxes and power distribution cabinets. It is equipped with an external open-close lightning current sensor, which has the characteristics of small size, simple installation, and high reliability. It can detect the multi-pulse current intensity (peak value), number, occurrence time, polarity and other information of line lightning strikes in real time.

    Product Features

    ● Compliant with IEC 61643-11;
    ● High-energy zinc oxide varistor core with exceptional discharge current capacity
    ● Ultra-fast response time
    ● Compact integrated design
    ● Visual red flag failure indication
    ● Thermal-controlled overheat tripping mechanism, interlocked with the red flag indicator
    ● CQC Certification

    Scope of Application

    ● Able to record the peak value, number, time and polarity of lightning multi-pulse current;
    ● Recording interval is up to 20ms;
    ● Able to send lightning strike information to the data center via RS485, TCP/IP or 4G;
    ● High lightning strike response sensitivity, small threshold and large range;
    ● The sensor adopts winding process design and has high acquisition accuracy;
    ● Open-type sensor is easy to install;

     Technical Specifications

    Model T03-B3
    Working voltage 12VDC
    Power consumption <2W
    Current measurement range ±(2~250) kA
    Sampling rate 1.5M
    Trigger mode Channel voltage signal trigger
    Working mode Continuous work
    Communication interface RS485
    Data storage MCU external FLASH storage
    Recording duration 1000ms
    Working temperature and humidity -25℃ ~ +55℃ ; 5%~95%RH
    Storage temperature and humidity -25℃ ~ +55℃ ; 5%~95%RH
    Enclosure protection level IP20
    Product dimensions (mm) 2079.581
    Sensor dimensions (mm) 997022 ( Note: The sensor center ring is Ø26 )
    Installation method 35mm rail
    Model T03-A6
    Working voltage 12VDC
    Power consumption <2W
    Current measurement range ±(2~250) kA
    Measurement channel 1
    Measurement information Lightning current peak value, occurrence time, number, polarity
    Measurement error ±5%
    Response speed 1 time/1s
    Data storage RS485、TCP/IP or 4G
    Number of records 20
    Working temperature and humidity -25℃ ~ +55℃ ; 5%~95%RH
    Storage temperature and humidity -25℃ ~ +55℃ ; 5%~95%RH
    Enclosure protection level IP20
    Product dimensions (mm) 2079.581
    Sensor dimensions (mm) 997022 ( Note: The sensor center ring is Ø26 )
    Installation method 35mm rail

    Basic Circuit Diagram

    T03-A6 Lightning Data Logger detail (2)

    Dimensions

    T03-A6 Lightning Data Logger detail (3)

    Installation Instructions

    T03-A6 Lightning Data Logger detail (1)

    Certificate

    • certificate01
    • certificate02

    Document Download

    Quality Inspection(Test reference)

    1 Inspection Reference
    IEC61643.11 Surge Protective Devices (SPD) for Low-Voltage Distribution Systems
    Part 1: Performance Requirements and Test Methods
    GB/T 2828.1-2012 Sampling Inspection Procedures
    Part 1: Sampling Plans for Inspection by Acceptance Quality Limit (AQL)
    2 Incoming Inspection
    Incoming material inspection is conducted based on the "Metal Parts Inspection Standard," "Plastic Parts Inspection Standard," "Electronic Parts Inspection Standard," "Auxiliary Materials Inspection Standard," and the GB/T 2828.1-2012 Sampling Inspection Procedure.
    3 Finished Products Inspection
    1) Routine test
    Routine inspection is a 100% inspection conducted at the final stage of production on products from the production line. After inspection, no further processing is done, except for packaging and labeling.
    2) Sampling test
    Sampling inspection is performed according to the GB/T 2828.1 sampling standard.
    3) Acceptance test
    Verification inspection is a sampling inspection conducted to ensure that the product continues to meet the standard requirements. Verification inspection should be carried out according to the procedures and frequency specified by the standard.
    Inspection Table

    Inspection Items

    Routine test

    Sampling test

    Acceptance test

    Packaging

     

    √

     

    Appearance Quality

    √

    √

    √

    Structure and Shape

    √

    Remote Signal Alarm Function

    √

    √

    √

    U1mA Value Test

    √

    √

    Markings and Labels

    √

    √

    √

    Direct Contact Protection Test

    √

    Standby Power Consumption and Residual Current

    √

    Protection Level

    √

    Action Load Test

    √

    Thermal Stability Test

    √

    √

    Temporary Overvoltage (TOV) Test

    √

    Mechanical Strength

    √

    Insulation Resistance

    √

    Dielectric Strength

    √

    Environment, IP Code

    √

    Electrical Clearance and Creepage Distance

    √

    Resistance to Abnormal Heat and Flammability

    √

    Status Indicator Operation

    √

    √

    √

    Isolation Between Separate Circuits

    √

    Transportation Vibration Test

    √

    Free Fall Test

    √

    Insertion and Withdrawal Force Test Before Surge Impulse (for Pluggable Modules)

    √

    √